CNAS-GL026:2018

第 81 页 共 114 页

- EUT 与频谱分析仪之间的链路 S 参数 0.724(m), 损耗 2.8dB(d)

u_{\text{EUT-功分器}} = \frac{0.7 \times 0.099 \times 100}{\sqrt{2} \times 11.5} = 0.426 \text{dB}

u_{\text{功分器-衰减网络}} = \frac{0.099 \times 0.333 \times 100}{\sqrt{2} \times 11.5} = 0.203 \text{dB}

u_{\text{衰减网络-频谱仪}} = \frac{0.333 \times 0.091 \times 100}{\sqrt{2} \times 11.5} = 0.186 \text{dB}

u_{\text{EUT-衰减网络}} = \frac{0.7 \times 0.333 \times 0.912 \times 0.912 \times 100}{\sqrt{2} \times 11.5} = 1.192 \text{dB}

u_{\text{功分器-频谱仪}} = \frac{0.099 \times 0.333 \times 0.794 \times 0.794 \times 100}{\sqrt{2} \times 11.5} = 0.128 \text{dB}

u_{\text{EUT-频谱仪}} = \frac{0.7 \times 0.091 \times 0.724 \times 0.724 \times 100}{\sqrt{2} \times 11.5} = 0.205 \text{dB}

\text{则 } u(\delta P_M) = \sqrt{0.426^2 + 0.203^2 + 0.186^2 + 1.192^2 + 0.128^2 + 0.205^2} = 1.318 \text{dB}

5.5.3.5 被测样供电电压变化引入的不确定度分量 u(\delta P_V)

在测试期间, 实验室供电电压可控范围为 0.1V, 根据 ETSI TR 100 028 表 F.1

- 均值 10%(p)/V

- 标准差 3%(p)/V

u(\delta P_V) = \frac{0.1V \times \sqrt{(10\% / V)^2 + (3\% / V)^2}}{\sqrt{3} \times 23.0} = 0.026 \text{dB}

5.5.3.6 时间周期变化引入的不确定度分量 u(\delta P_D)

根据 ETSI TR 100 028 表 F.1, 时间周期误差为 2%(d)(p)( \sigma )

u(\delta P_D) = \frac{2\%}{23.0} = 0.087 \text{dB}

5.5.4 不确定度概算

表 5-10 传导杂散发射测量不确定度概算表

分量 概率分布 灵敏系数 不确定度分量值 (dB)